Centralised exhaust air unit

ZEG2 EC

Article number: 0086.0206
Manufacturer: MAICO
Centralised exhaust air unit with humidity sensor/humidity control without heat recovery, with EC technology... more information
Application examples: Low-energy house, Single-family house, Apartment, Living room, Redevelopment
Product data sheet
ZEG2 EC IM0016914.PNG Centralised exhaust air unit with humidity sensor/humidity control without heat recovery, with EC technology and wireless remote control

Characteristic curve

ZEG2 EC - Characteristic curve Pressure losses - DIP switch 7 "Off"

afw - absent

Factory setting:

Low (1a)

Normal (3a)

High (11a)

ZEG2 EC - Characteristic curve Pressure losses - DIP switch 7 "On"

afw - absent

Dimensioned drawing

ZEG2 EC - Dimensioned drawing [mm]

  1. Exhaust air connection
  2. additional exhaust air connection with knockout point
  3. Outgoing air socket

Technical data

ZEG2 EC - Technical data

Article ZEG2 EC
Air flow volume 535 m³/h / 600 m³/h / System pressure at 200 Pa and/or system pressure at 100 Pa
Speed controllable
SEC average -20,6 kWh/(m²*a)
Energy efficiency class D
Type of voltage Alternating current
Rated voltage 230 V
Frequency 50 Hz
Power consumption 2 W - 85 W
Imax 0,05 A - 0,8 A
Degree of protection IP 20
Installation site Cellar / Storage tank / Jamb wall / Utility room / Heating room / Engineering room
Installation position vertical / horizontal
System type Centralised
Material Synthetic material
Colour white
Weight 4,59 kg
Weight including packaging 5,14 kg
Connection diameter 125 mm
Width 443 mm
Height 463 mm
Depth 303 mm
Width with packaging 455 mm
Height with packaging 485 mm
Depth with packaging 315 mm
Packing unit 1 piece
Range K
GTIN (EAN) 4012799862062
Article number 0086.0206

 

63 Hz

125 Hz

250 Hz

500 Hz

1 kHz

2 kHz

4 kHz

8 kHz

Total

LWA2, S1 (dB(A))

26

22

17

14

14

16

17

17

28

LWA2, S2 (dB(A))

37

39

34

30

23

20

17

17

37

LWA2, S3 (dB(A))

45

43

50

41

33

29

21

18

46

LWA2= housing sound power level in dB.

Measured in accordance with factory setting (3 levels)

Accessories

ZEG2 EC - Accessories

General accessories

Product type Name Art. No. Price*(EUR) Action
Flexible duct MA-FR flexible duct - - -
Roof outlet DF - - -
Roofing tile DP - - -
Mounting clamp BS - - -
Rain protection grille RG - - -
MAICOTherm ventilation duct system, thermally insulated MAICOTherm MT thermally-insulated ventilation duct system - - -
MAICOFlex ventilation duct system, round Flexible round MAICOFlex MF ventilation duct system - - -
MAICOAir ventilation duct system, round Flexible, round MAICOAir MA ventilation duct system - - -
MAICO FFS ventilation duct system, flat MAICO FFS flexible flat ventilation duct system - - -
MAICOFlex ventilation duct system, round Flexible round MAICOFlex ventilation duct system - - -
Roofing tile DP - - -
MAICO FFS ventilation duct system, flat MAICO FFS flexible flat ventilation duct system - - -
Stainless steel cowl LH-V2A 12 0151.0378 on request
  • On the notes
Stainless steel cowl LH-V2A 15 0151.0379 on request
  • On the notes
Outgoing air wall connection KW-FL 12E 0152.0075 on request
  • On the notes
Outgoing air wall connection KW-FL 12W 0152.0076 on request
  • On the notes
Outgoing air wall connection KW-FL 16E 0152.0079 on request
  • On the notes
Outgoing air wall connection KW-FL 16W 0152.0080 on request
  • On the notes
Outside air opening ALD 10 0152.0054 on request
  • On the notes
Outside air opening ALD 125 0152.0067 on request
  • On the notes
Outside air opening ALD 125 VA 0152.0068 on request
  • On the notes
Outside air opening ALD 160 0152.0069 on request
  • On the notes
Outside air opening ALD 160 VA 0152.0070 on request
  • On the notes
Internal grille ESG 10/2 0059.0947 on request
  • On the notes
Door ventilation grille MLK 30 white 0151.0123 on request
  • On the notes
Door ventilation grille MLK 45 white 0151.0126 on request
  • On the notes
Exhaust and supply air valve AZV 100 0152.0087 on request
  • On the notes
Disk valve, synthetic material TK 10 0151.0192 on request
  • On the notes
Disk valve, synthetic material TK 12 0151.0198 on request
  • On the notes
Disk valve, metal TM 10 0151.0194 on request
  • On the notes
Disk valve, metal TM 12 0151.0196 on request
  • On the notes
Disk valve, stainless steel TM-V2A 10 0151.0374 on request
  • On the notes
Disk valve, stainless steel TM-V2A 12 0151.0375 on request
  • On the notes
Disk valve, metal TFA 10 0151.0369 on request
  • On the notes
Disk valve, metal TFA 12 0151.0370 on request
  • On the notes
Mounting frame for TFA/TFZ EBR-D 10 0092.0493 on request
  • On the notes
Mounting frame for TFA/TFZ EBR-D 12 0092.0494 on request
  • On the notes
Grease filter element for exhaust air FFE 10 0092.0506 on request
  • On the notes
Flexible aluminium duct AFR 125 0055.0091 on request
  • On the notes
Tubular sound absorber RSR 12 Discontinued product 0092.0312 on request
  • On the notes
Tubular sound absorber RSR 12/50 Discontinued product 0092.0322 on request
  • On the notes
Tubular sound absorber RSR 12-1 New development 0092.0593 on request
  • On the notes
Tubular sound absorber RSR 12/50-1 New development 0092.0601 on request
  • On the notes
Slide-in sound absorber SDE 8 0044.0213 on request
  • On the notes
Slide-in sound absorber SDE 10 0044.0214 on request
  • On the notes
Slide-in sound absorber SDE 12 0044.0215 on request
  • On the notes
Stainless steel cowl LH-V2A 16 No longer available for delivery 0151.0380 on request
  • On the notes
Internal grille, adjustable AZE 100 No longer available for delivery 0059.0959 on request
  • On the notes
Outside air opening ALD 10 T No longer available for delivery 0152.0055 on request
  • On the notes
Outside air opening ZE 45 F white No longer available for delivery 0152.0044 on request
  • On the notes

Product description

Productdescription

ZEG2 EC

short description

Centralised exhaust air unit with humidity sensor/humidity control without heat recovery, with EC technology and wireless remote control

Product description

Features

  • Centralised air extraction unit.
  • For simultaneous air extraction of a number of rooms in single family-unit houses or flats.
  • IP 20 degree of protection.
  • Easy-to-clean housing.
  • The unit is fitted with a quiet-running and energy-efficient electric motor.
  • With 5 possible exhaust air connections (3 x DN 125, 1 x DN 125/DN 160) and 1 x DN 160 = "knockout point")
  • With a DN 125 outgoing air socket.
  • Motor and electronics are integrated.
  • Max. 28 speed levels are available.
  • Levels 1(a*) = "Low", 3(a*) = "Normal" and 11 (a*) = "High" are preset as standard.
  • The preset speed levels can be easily changed using what are known as DIP switches.
  • With integrated humidity sensor for automatic humidity-dependent activation.
  • ZEG2 EC-FB wireless remote control included in scope of delivery.
  • * = the "a" characteristic curve and "b" characteristic curve exist depending on the setting of DIP switch 7.

Controller

  • ZEG2 EC-FB wireless remote control with humidity sensor activation and 6 setting buttons (humidity sensor is contained in ZEG2 EC).
  • Radio frequency 868.3 MHz.
  • Dimensions (HxWxD): 83x80x28 mm.
  • Degree of protection: IP 30.
  • LED status display.
  • Settings
    • Operation during periods of absence ('energy-saving mode')
    • Automatic operation regulates the ventilation level in accordance with the humidity sensor measurements established
    • Timer operation (15/30/60 minutes) in 'High' level – then back to the last level selected
    • 1. Low speed – standard position during the night
    • 2. Normal speed – standard position during the day
    • 3. High speed – when cooking and showering
  • About automatic mode: In this position the exhaust air unit runs at a lower speed until a significant increase in the relative air humidity in the exhaust air is measured within 3 minutes (can be set to 5 % or 10 % with DIP switch 7). The unit then switches from the "Low" (1) level to "Normal" (2) or "High" (3) depending on setting of DIP switch 7. If there is a noticeable drop in the humidity level, the ZEG2 EC runs for 15 or 30 minutes at 'Normal' or 'High' level (overrun time is set with DIP switch 8). It then switches back to 'Low' level.
  • About operation during periods of absence: The ZEG2 EC runs in energy save mode and does not react to the humidity sensor

Mounting instructions

  • The ZEG2 EC-FB remote control can be installed in damp rooms - but not in the shower cubicle itself. The remote control must not be sprayed (relative humidity of max. 90 %).
  • The ZEG2 EC unit must be installed in a dry room - it must not come into contact with any spray (relative humidity of max. 90 %).

Electrical connection

  • Flexible connecting cable, approx. 1.2 m long.

Table of contents

Wiring diagram

ZEG2 EC - Wiring diagram



Predecessor - successor

ZEG2 EC - Predecessor

Product type Name Art. No. Action
Centralised exhaust air unit ZEG EC No longer available for delivery 0086.0205
  • On the notes

Notes
Inquiry
Product comparison
The wish list option allows you to make a note of all the products you are interested in. You can change your wish list as often as you want to. You can change the quantity and item position of the products, go back to the product page, download product data sheets, delete items and mark products as optional. You can save your wish list to your computer and then call it up again at a later time to make more changes, if required. Using the list, you can then download the tender text for all the products you have saved to the list, create an enquiry or compare products.
Assort Product type Name Art. No. PDF Range List price* (EUR) Quantity Optional Total gross amount (EUR)
There are no products on the list
Save wish list on local computer
Load wish list from local computer

On this website, technologies such as cookies and measurements of reach (targeting and tracking) are used (services). This means that personal information such as the IP address and browser information is processed to continuously improve our website as well as to display to you customised content that corresponds to your individual interests. You may of course influence the use of this information through the settings you choose. The settings you have chosen are stored in a necessary selection cookie. With the exception of the selection cookie mentioned above, technically non-essential cookies and measurements of reach are only used if you provide permission in advance by clicking “ACCEPT ALL AND CLOSE”. Details and options for customising your consent can be found under Data protection settings.

Here you can select a variety of different categories of services or cookies. By activating the corresponding “Statistics & analytics” checkbox and confirming “Save settings”, you can give your informed consent to the use of cookies for customisation purposes. At the bottom of the website under “Data protection settings”, you can change or revoke your consent and settings for the individual services at any time with effect for the future.

Necessary cookies are absolutely necessary for the operation of the website. Without these cookies, the website would not function properly.

These cookies and services collect and process data for statistics and analytics and thus enable further improvements of this website for users. Google Analytics and Google Adwords Conversion are used for this purpose. You will find a detailed description of such use in our Privacy Policy.

Save settings ACCEPT ALL AND CLOSE Data protection settings